Abstract
Various methods have been proposed to measure fracture aperture distributions, including X-ray computed tomography (CT) imaging, which has the advantage that it can be combined with dynamic flow experiments. In this paper, we present a calibration-free missing CT attenuation (CFMA) imaging method for measuring fracture apertures that avoids time-consuming calibration. In addition, this model does not assume a homogeneous matrix and thus provides a good estimate of fracture apertures even when rock properties are heterogeneous. The validity of the CFMA model is established by four approaches: comparing apertures calculated with the conventional calibration-based method; evaluating model predictability at different scanner voxel sizes; comparing with calibration coefficients in the literature from a number of experiments with different rocks and X-ray scanners; and comparing aperture measurements for dry and wet scans. We analyze the systematic error and the random error introduced by rock heterogeneities and CT scanning and show that by averaging 5 replicate scans, we reduce the aperture measurement error to ∼22 µm.
INTRODUCTION
Efforts to quantify fracture geometry and tortuosity and their relationship to fracture permeability have been ongoing for decades. Of particular interest are the mechanical opening of fractures, or the aperture, and their spatial distribution. Various methods have been proposed and implemented to measure fracture apertures and to characterize fracture void geometry. Representative techniques (Committee on Fracture Characterization and Fluid Flow et al., 1996) include (1) those that use measurements of surface profilometry; (2) those that involve material filling in the void space; and (3) those that apply noninfiltrative technology, such as computed tomography (CT) scanning.
Table 1 lists 10 methods for measuring fracture apertures (Glover et al., 1998; Isakov et al., 2001; Boutt et al., 2006; Bandis, 1980; Committee on Fracture Characterization and Fluid Flow et al., 1996; Gale, 1987; Billaux and Gentier, 1990; Pyrak-Nolte et al., 1987; Schrauf and Evans, 1986; Barton et al., 1985; Ketcham et al., 2010). The advantages and disadvantages of the methods are also listed. As Table 1 shows, the CT scanning technique alone has the advantage that it can be combined with core-flooding experiments to measure properties such as relative permeability and capillary pressure, stress-dependent transport properties, or reactive chemical transport phenomena, and it is therefore the focus of this paper.
Methods for using X-ray CT scanners to measure fracture apertures have been under development since the 1990s (Johns et al., 1993; Ketcham et al., 2010). There are three alternative conceptual approaches for calculating fracture apertures from CT data, denoted as peak height (PH), full-width-half-maximum (FWHM), and missing CT attenuation (CTMA) in Figure 1. The black line shows a hypothetical transect across the two fractures shown in the inset, which is obtained from an X-ray scan of a rock slice. For this example, the rock matrix has an average CT number of 1250 Hounsfield units (HU), and the presence of a fracture is indicated by lower CT numbers. The HU scale is a representation of the material radiodensity. The CT number of distilled water at standard temperature and pressure (STP) is defined as 0 HU, while the CT number of air at STP is defined as –1000 HU (Hounsfield, 1980).
The area shown by the shaded regions in Figure 1 is called CTMA, which refers to the deficit of density (and, accordingly, X-ray attenuation measured in CT numbers) caused by a fracture filled with air or any other fluid. The first method for calculating fracture aperture, shown in Figure 1, uses the so-called FWHM value, i.e., the width of the transect measured at the midpoint CT number between the air and the rock matrix (125 HU in Fig. 1). One of the drawbacks of the FWHM method is that for thinner apertures, the decrease in CT number may not be sufficiently large to reach the midpoint, and FWHM consequently cannot be used to calculate the aperture (Ketcham and Carlson, 2001). The second method (Fig. 1) uses PH, which corresponds to the difference between the CT number of the rock matrix and the minimum CT value measured across the fracture (Vandersteen et al., 2003). The PH method fails when the fracture aperture is large enough for the minimum CT number to reach the attenuation of air, thus becoming insensitive to the width of the aperture. Note that both the FWHM and PH methods need careful calibration to obtain the relationship between fracture apertures and FWHM/PH. The third method, the CTMA, is shown in the shaded area of Figure 1. This method calculates the CTMA due to the presence of the fracture (Johns et al., 1993; Keller, 1997; Van Geet and Swennen, 2001). The method assumes that all X-ray attenuation is conserved in CT scanning and that the aperture of a fracture can be ascertained if its total attenuation signal can be delineated and integrated. It has been shown that by capturing the density deficit caused by the presence of a fracture, the CTMA method provides for the most accurate estimates of fracture apertures over a wide range of values (Ketcham et al., 2010).
Although the conventional CT method can be used to measure fracture apertures, it has several shortcomings in the way that it is conventionally applied: first, it requires a significant effort for calibration, normally two to three days for four calibration points using spacers of different thicknesses; second, it typically assumes a homogeneous core, as indicated by the constant in Equation 2. As an alternative to calibration using spacers, Ketcham et al. (2010) demonstrated that apertures could be calculated using an absolute scale, which only requires measuring the CT numbers for the rock matrix and air; however, they concluded that it was difficult to determine the CT value for air inside the core holder due to factors such as beam hardening and image reconstruction artifacts when there are large contrasts between materials.
Ketcham et al. (2010) proposed an enhancement of the CT method that uses a point-spread function (PSF) to relate fracture aperture and variation of the CT numbers across the fracture. By evaluating the shape of the CT traverses over the fracture, accurate measurement of fracture apertures can be obtained through the inverse PSF method (IPSF). IPSF deals very well with heterogeneity, even for highly heterogeneous materials. With IPSF, apertures of one-tenth of a voxel width can be detected and determined. In general, IPSF provides a robust way to calculate aperture distributions; however, it requires complex numerical deconvolution and is thus more computationally expensive. In addition, the IPSF method does not eliminate the need for a calibration process.
The objective of this paper is to present a more efficient method based on the missing attenuation (MA) approach for calculating fracture aperture distributions that does not require calibration and can be used in heterogeneous rocks with error quantification. The method, referred to here as the CFMA (calibration-free missing attenuation) method, builds on and extends the absolute calibration method described in Ketcham et al. (2010).
SIMPLIFIED METHOD FOR APERTURE MEASUREMENT USING CT SCANNING
The CT number in the vicinity of the fracture is reduced due to the density deficit of the fluid-filled or air-filled fracture. Low CT numbers occur both in the voxels at the fractures and adjacent voxels due to smearing of the X-ray attenuation and so-called partial volume effects (Weerakone and Wong, 2006). The partial volume effect causes the CT number to decrease in the voxels adjacent to the fracture when only a portion of the voxel is filled with rock. Moreover, when material properties change rapidly, smearing of X-ray attenuation occurs due to the finite beam width and oversampling associated with X-ray computed tomography (Johns et al., 1993). These two effects prevent voxels at a density discontinuity from responding sharply to density contrasts. Depending on the rock type and the aperture size, for a scanner with a spatial resolution of 0.5 mm, most of the fractures will affect ∼5–6 voxels. Figure 2 illustrates this: three one-dimensional (1-D) transects across a rock slice are shown that represent a hypothetical fracture of width d filled with air (left transect) and the corresponding profile that would be imaged from an X-ray scan (transect in the center) with resolution R. For the sake of simplicity, this illustrative example considers a fracture having a width that corresponds to the resolution of the scanner; note that the process could be repeated for a fracture with an arbitrary width, and the analysis and conclusions that follow would not be affected.
For highly heterogeneous materials, the CT numbers might continue increasing from the fracture for more than three voxels. This will cause inaccuracies in the CFMA method; however, examination of the scans can be used to assess whether this is problematic for any particular rock sample. Errors associated with the estimation of CTMA are described herein (see the Discussion). As to the application of the CFMA method, the use of Equation 6 accounts for heterogeneity in the rock properties by using local values for CTmat.
APPLICATION OF THE CFMA METHOD
Materials
Two rock samples were used to test and evaluate the CFMA method; a high-porosity (∼22%) Berea Sandstone core (Cleveland Quarries, Vermilion, Ohio, USA) and a low-porosity (< 4%) silicate-cemented sandstone core from southern Israel, which was collected from the Zenifim Formation at a depth of ∼1770 m and preserved at the archive of the Geological Survey of Israel. Both samples have a single centered saw-cut fracture that crosses the core through its entire length. The fracture is smoother for the highly cemented Zenifim sandstone as compared to that in the Berea Sandstone, where grains are removed from the surface during sawing. The Berea Sandstone has a length of 8 cm, and the Zenifim sandstone has a length of 6.7 cm; both samples have a diameter of 5 cm.
Imaging Methods
Imaging was carried out as follows: the dried core sample was wrapped in a sleeve with layering from the core outward of one layer of heat-shrinkable Teflon and a Viton rubber sleeve, mounted in an aluminum core holder, and a slight annular pressure (water) of 0.34 MPa was applied to keep the core halves together. The core holder is then placed horizontally in a medical X-ray CT scanner (General Electric HiSpeed CT/i X-ray) that is used to image the fractured samples. The calibration uses spacers made from tin of various widths (∼0.20, 0.30, 0.40, 0.50 mm). The spacers are placed between the two rock surfaces, separately at the inlet, the center, and the outlet of the rock sample, and scans are taken at positions between the spacers (for a total of four different slices). For the measurements without spacers, the entire core is imaged. Unless otherwise stated, the following imaging parameters have been applied in this study: voxel dimension of (0.5 × 0.5 × 1) mm3, a display field of view of 25 cm, a tube current of 200 mA, and an energy level of 120 keV. CTMA due to the presence of the fracture is calculated using Equation 1. Calculating the CTMA due to the presence of a fracture requires data cropping, classification, and identification of fracture features (Karpyn et al., 2009). The location of the fracture is identified with the lowest CT number within the trough, which extends on both sides of the fracture until the point where the CT number stops increasing. The definition of the trough edge might result in an increased matrix CT number estimate, which will increase the calculated CTMA and further raise the fracture aperture measurement. The matrix CT number CTmat is calculated by averaging the CT numbers of six adjacent voxels next to the trough region (three on each side). The fracture aperture is then calculated either with Equation 6 or through the calibration method, as suggested in previous studies. To reduce the random noise that affects X-ray images, multiple scans are taken at identical locations and averaged, following a protocol presented in Pini et al. (2012). For the calibration, 20 repeated scans are taken and averaged to further reduce the CT scanning error.
Fracture Aperture Measurement Using the Conventional Calibration Method
Illustrative snapshots of X-ray scans acquired with different spacers within both fractured samples are shown in Figure 3. Figure 4 shows the corresponding transect lines that pass through a given location of the core for the Berea Sandstone sample. While the number of voxels spanning the trough region remains constant (five voxels in the figure), the CT number in the fracture region drops gradually with larger spacers, and reaches almost 100 HU for the 0.5-mm-thick spacer. The missing attenuation increases accordingly with aperture size.
CTMA values were calculated with Equation 1 at four distinct locations (slices) within the rock sample and with four different spacers (for a total of 380 points/spacer). Because the fracture surface is rough, the calculated CTMA for each spacer is expected to have a wide distribution (broader for the Berea Sandstone than for the fine-grained Zenifim sandstone sample). The histogram distribution of CTMA values for the 0.53-mm-thick spacer is shown in Figure 5 (inset on left). The CTMA of the fracture is normally distributed; accordingly, vertical bars are added to each symbol in Figure 5 to represent the spread of the distribution. As expected from those methods that use a calibration to define the relationship between CTMA and fracture aperture, CTMA is linearly proportional to spacer thickness. Because the fracture surface is not perfectly smooth, the regression line does not pass through the origin, suggesting that the initial aperture caused by the roughness of the fracture surface is 0.14 ± 0.01 mm and 0.08 ± 0.01 mm for the Berea and Zenifim samples, respectively. Uncertainties of both the slope (M) and the intercept are calculated (Taylor, 1997). In order to build the calibration curve used in calibration methods to estimate fracture aperture, the regression line is shifted to cross the origin of the axes; for the Berea and Zenifim samples, the slopes of these lines are 4512 and 5890 (HU/mm), respectively. According to Equation 6, the slope of the calibration lines should be equal to , when the average rock matrix CT number is used (1250 HU for Berea Sandstone and 1800 HU for Zenifim sandstone). Accordingly, the slopes for the Berea Sandstone and Zenifim sandstone are expected to be 4500 and 5600 HU/mm, respectively, in agreement within <1% and 5%, respectively, of the slopes calculated from the data.
Note that the use of a calibration line implicitly assumes that the denominator in Equation 5 is a constant, implying that the CT number of the matrix does not vary spatially within the rock. While this may be satisfactory when the average fracture aperture is computed, this assumption has to be relaxed when the goal is to determine aperture distribution of the fracture.
VALIDATION OF THE CFMA METHOD
To evaluate the accuracy and validity of the CFMA method, we apply four tests: linearity between CTMA and resolution of the scanner, as predicted by Equation 6; comparison of the aperture distribution using the conventional calibration-based approach and the CFMA method; comparison between fitting parameters from literature data and predictions using Equation 6; and comparison between aperture distributions made using dry and wet scans.
Linearity Between CTMA and CT Scanner Resolution
To confirm the relationship between CTMA and CT scanner resolution, we conducted a set of experiments under variable fields of view: 10, 15, 20, and 25 cm. The experiments are conducted without spacers, and thus the whole sample is scanned. The corresponding voxel dimensions are (0.2 × 0.2 × 1) mm3, (0.3 × 0.3 × 1) mm3, (0.4 × 0.4 × 1) mm3, and (0.5 × 0.5 × 1) mm3. The computed CTMA is plotted in Figure 6 as a function of the reciprocal of CT scanner resolution, and a linear relationship is found. The dashed line in Figure 6 is the prediction using Equation 6 based on the average matrix CT number (1250 HU for Berea Sandstone and 1800 HU for Zenifim sandstone) and the average fracture aperture (0.099 mm for Berea Sandstone and 0.040 mm for Zenifim sandstone); as shown in Figure 6, it agrees well with the CTMA at different CT scanner resolutions.
Comparison between the Calibration Method and the CFMA Method
We compare apertures calculated with the conventional calibration-based method and the CFMA method. Table 2 shows the differences between fracture apertures for both rocks obtained by using Equation 6 and those obtained from the calibration lines shown in Figure 5. Results are reported in terms of mean apertures and standard deviations, using data generated with spacers spanning 0.2–0.5 mm. In this comparison, the calibration-based method uses a single calibration curve for the whole core, and thus assumes that the core is homogeneous. In contrast, the CFMA method does not require the rock to be homogeneous; instead, it uses local values for CTmat in Equation 6. The mean values and standard deviations of the calculated apertures obtained from the two methods agree very well, with a 1% and 3% difference for mean apertures of the Berea Sandstone and Zenifim sandstone, respectively. The standard deviation differences are slightly larger for the CFMA method ranging from 2% to 9% for the Berea Sandstone and Zenifim sandstone, respectively. Larger differences between the two methods are expected for less homogeneous rocks, because the CFMA method explicitly accounts for the influence of heterogeneity.
As a second test, shown in Figures 7 and 8, we compare aperture distributions calculated using the calibration method and the CFMA method when no spacer is present. Both the Berea Sandstone and the Zenifim sandstone are compared. The 2-D fracture images, aperture distributions, and voxel-by-voxel comparisons show that the agreement between the two methods is excellent. The agreement between the aperture distributions calculated using the CFMA method and the traditional calibration-based approach provides further confirmation that the errors associated with assuming CTair is –1000 are negligible.
Comparison between Literature Data and CFMA Model Prediction
Results of nine experiments from different authors are examined to evaluate the validity of the CFMA method (Keller, 1997; Bertels et al., 2001; Johns et al., 1993; Weerakone and Wong, 2006; Muralidharan et al., 2004; He, 1998). Comparison between the reported calibration coefficients and the values predicted using Equation 6 (using published values for CTmat and the CT scanner resolution) are shown in Figure 9 and Table 3. Agreement is very good, and outliers are only found in Weerakone and Wong (2006) and He (1998). The mismatch might be caused by insufficient information on calculating the MA baseline.
Fracture Aperture Measurements Using Dry and Wet Scans
We further compare the aperture fields measured with water-filled and air-filled fractures. For the water-filled fracture, CTwat (equal to 0 HU) is used instead of CTair in Equation 6. Figure 10 shows the experimental data from the fractured Berea Sandstone. The average aperture for the dry scan is 0.112 mm and the average aperture for the wet scan is 0.113 mm. The difference between the two measurements is provided in Figure 10, which also shows that the distribution of the aperture differences exhibits a normal distribution with mean of –0.0007 mm and standard deviation of 0.043 mm. Good agreement between the values shows that the CFMA method can also be applied to water-filled fractures and provides additional confirmation that using a value of CTair of –1000 HU is satisfactory when using a medical scanner for making fracture aperture measurements.
DISCUSSION
As described in the following, combining the systematic error and random error, the total measurement error is ∼22 μm with 5 scans using a resolution of 500 μm, which is less than one-twentieth of the voxel size.
Systematic Error
The unavoidable use of a baseline CT value to represent the intact rock matrix (CTmat) in the calculation of CTMA introduces a source of error. In this study, this error has been independently quantified by comparing fracture apertures calculated using Equation 5, which provides the true value for the aperture, and Equation 6, which provides the value based on assuming that CTmat can be approximated by the three adjacent voxels on either side of the fracture. To provide a rigorous test of the systematic error, calculations are made by introducing virtual fractures of 100 and 500 μm into the scans. Smearing associated with image reconstruction and other scanning artifacts is added to the 5 voxels adjacent to the fracture such that the CTMA equals that expected for 100 or 500 μm apertures. Figure 11 summarizes this analysis by showing histogram plots of the deviation between true (Equation 5) and computed (Equation 6) apertures for the 100 and 500 μm fracture for scans with an image resolution of 500 μm. In each case, 1650 independent realizations have been performed by placing the given fracture at arbitrary positions within rock slices of a Berea Sandstone core. In both cases, the observations are normally distributed around the true fracture apertures (mean d – dtrue = 0.5 μm for the 100 μm fracture and d – dtrue = 0.3 μm for the 500 μm fracture) with standard deviations of ∼21 μm. The error introduced by assuming a local baseline CT value for the rock matrix will affect the experimentally estimated fracture aperture with an uncertainty of 21 μm. It is interesting that the repetition of this calculation by imposing the baseline as being the average CT number of the entire slice leads to results that are normally distributed (with similar standard deviations of ∼21 μm), but with their mean significantly shifted from zero, i.e., with values of d –dtrue = 6 μm for 100 μm fracture and 5 μm for 500 μm fracture. We conclude that when compared to calibration methods that assume a transect-, a slice- or a core-averaged value for CTmat, the use in this study of a local value allows us to better capture the inherent spatial heterogeneity of the rock’s matrix, while it reduces the systematic error introduced by imposing an arbitrary baseline.
Random Error
For the rocks tested here, σd ≈ 7 μm with 5 scans; if only 2 scans are used, the measurement error is ∼13 μm. The size of the random error has been validated using the method described by Pini et al. (2012) and was described in detail in Huo (2015).
The overall uncertainty affecting fracture aperture estimates include contributions from both the random noise affecting X-ray measurements (σd = 7 μm) and the assumption on the matrix baseline discussed herein (see Systematic Error) (σd = 21 μm). The total error is estimated by summing the squares of these two values, thus resulting in a total uncertainty of ∼22 μm when the voxel size is 500 μm. Note that we focus here on horizontal fractures. If the fracture is not horizontal or perpendicular, the associated error of fracture aperture measurement could increase because of the Cartesian geometry of the reconstructed image.
For the conventional calibration method, the error is a combination of both the linear fitting error (Fig. 5) and the error of CTMA. By applying the similar error analysis in Equation 16, the standard deviation of aperture measurement is ∼28 μm with a single scan, which is very close to the standard deviation of 25 μm from Bertels et al. (2001) using a 310 μm voxel size.
CONCLUSIONS
We have developed a calibration-free missing CT attenuation (CFMA) method for calculating fracture apertures using X-ray CT imaging without time-consuming calibration. Four tests have been applied to test the method’s validity based on two rock cores and the literature. The results of these tests suggest that the method provides reliable aperture measurements. Error analysis shows that the method provides a measurement error of 22 μm when 5 replicate scans are averaged, which is less than one-twentieth of the voxel size. Benefits of the CFMA approach include the following.
The CFMA method provides a much more convenient and efficient way to relate fracture aperture and CTMA. For a calibration with four spacers, the majority of the time is conventionally spent on core holder mounting and CT scanner machine time. With the CFMA method, the time required for making a set of aperture measurements can be reduced from several days to several hours. Moreover, opening the core holder to adjust the spacers and repositioning it in the field of view introduces additional errors for the measurements.
Uncertainty due to random errors is highly reduced by repeated scans, resulting in improved resolution of the fracture apertures. By applying 5 scans, which normally takes 2 h for a core length of 7 cm, the random error can be reduced by 50% compared with a single scan. Repeated scans can also increase the accuracy of matrix CT number, which will reduce the error of the aperture calculation.
The method is particularly valuable for combining dynamic core flood experiments with simultaneous aperture measurements, for example, in the study of stress-dependent permeability in fractured rocks (Huo and Benson, 2015). The CFMA method can also be used with water-filled fractures, by substituting CTwat for CTair in Equation 6.
This work focuses mainly on sedimentary rocks. The CFMA method may be applicable to other kinds of rocks. The corresponding errors of the method need to be investigated depending on the heterogeneities of the rocks and the extent of beam hardening.
The CFMA method demonstrates that the calibration of Hounsfield units embedded in this scanner is sufficient to provide accurate aperture measurements. Other methods, such as IPSF, could potentially use the same approach to eliminate the need for a calibration process. We advise verification of the applicability of the CFMA method for their specific instrument and experiment setups.
This work has been supported by Eni S.p.A. (Rome, Italy). We are grateful to Rani Calvo from the Geological Survey of Israel for providing the Zenifim sandstone sample used in this study.