1-20 OF 1032 RESULTS FOR

steel moment-frame buildings

Results shown limited to content with bounding coordinates.
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Article
Published: 01 November 2019
Earthquake Spectra (2019) 35 (4): 1611–1635.
... Performance-Based Seismic Design Methods for New Steel Buildings, Volume 1: Special Moment Frames , NIST Tech. Note 1863-1 , National Institute of Standards and Technology , Gaithersburg, MD . Haselton C. B. Baker J. W. Bozorgnia Y...
FIGURES | View All (13)
Journal Article
Published: 01 February 2015
Earthquake Spectra (2015) 31 (1): 273–292.
... on building sidesway response during an ensuing fire, an analytical case study is developed for a steel special moment-frame building with a seismic hazard representative of coastal California. Response data from numerical earthquake simulations indicate that damage to SFRM insulation in beam hinge regions...
FIGURES | View All (15)
Journal Article
Published: 01 November 2006
Earthquake Spectra (2006) 22 (4): 1035–1061.
... steel moment-frame buildings, one existing and one new, located in southern California due to ground motions from two hypothetical magnitude 7.9 earthquakes on the San Andreas Fault. The new building has the same configuration as the existing building but has been redesigned to current building code...
Journal Article
Published: 01 August 2006
Bulletin of the Seismological Society of America (2006) 96 (4A): 1523–1537.
... Fernando basins, and the resulting damage to two 18-story steel moment-frame buildings in the region. Each of these parts requires simulation at very different temporal and spatial scales that are best performed using task- specific software. Seismic-wave propagation can be modeled in a linear viscoelastic...
FIGURES | View All (8)
Journal Article
Published: 01 August 2004
Earthquake Spectra (2004) 20 (3): 883–915.
... Earthquake Engineering Research Institute 2004 Earthquake Engineering Research Institute Modeling and Response Prediction in Performance-Based Seismic Evaluation: Case Studies of Instrumented Steel Moment-Frame Buildings Sashi K. Kunnath,a)M.EERI, Quan Nghiem,b) and Sherif El-Tawilc) An evaluation...
Journal Article
Published: 01 May 2003
Earthquake Spectra (2003) 19 (2): 317–334.
...-frame design, evaluation, and upgrade procedures. FEMA-351, Recommended Seismic Evaluation and Upgrade Criteria for Existing Welded Steel Moment-Frame Buildings , was developed to evaluate the probable performance of existing steel moment-frame buildings in future earthquakes and to provide guidance...
Journal Article
Published: 01 May 2003
Earthquake Spectra (2003) 19 (2): 399–414.
...Maryann T. Phipps, M.EERI In the wake of a potentially damaging earthquake, every affected welded steel moment-frame building should be assessed to determine whether it poses a safety risk. A straightforward, multi-step process has been developed to streamline this formidable task. This paper...
Journal Article
Published: 01 May 2003
Earthquake Spectra (2003) 19 (2): 365–384.
...Charles A. Kircher, M.EERI This paper describes procedures that may be used by experienced structural engineers to develop earthquake damage and related loss functions for welded steel moment-frame (WSMF) buildings. The damage and loss functions are based on and compatible with the loss estimation...
Journal Article
Published: 01 May 2003
Earthquake Spectra (2003) 19 (2): 385–397.
... with Profes- REHABILITATION OF A 1985 STEEL MOMENT-FRAME BUILDING 387sor Michael Constantinou (1998) indicates that various materials have been tested over the last ten years and none have been found to deliver a long-term constant friction co- efficient. Further, research by Canadian engineers has indicated...
Journal Article
Published: 01 November 2011
Earthquake Spectra (2011) 27 (4): 1147–1168.
...H. Kit Miyamoto; Amir S. J. Gilani; Akira Wada; Christopher Ariyaratana An innovative design using steel special moment frames sized per building code requirements for strength and viscous dampers to control story drift ratios results in longer period structures that limit floor accelerations...
FIGURES | View All (12)
Journal Article
Published: 01 May 2021
Earthquake Spectra (2021) 37 (2): 1199–1222.
... of ground motions. This is partly attributed to the lack of existing databases of building designs, nonlinear structural models, and simulated seismic responses. This article introduces the development of a comprehensive database, which includes 621 special steel moment-resisting frames designed...
FIGURES | View All (21)
Journal Article
Published: 01 May 2003
Earthquake Spectra (2003) 19 (2): 309–315.
...Robert E. Shaw, Jr. FEMA-353, Recommended Specifications and Quality Assurance Guidelines for Steel Moment-Frame Construction for Seismic Applications , contains numerous provisions related to the materials, details, quality, and inspection of steel moment-frame buildings in seismic regions...
Journal Article
Published: 01 August 2004
Earthquake Spectra (2004) 20 (3): 951–973.
...Bruce F. Maison, M.EERI; Tom H. Hale, M.EERI The two-story welded steel moment-frame (WSMF) essential services building had columns severed by the 1994 Northridge earthquake. Two of eight columns suffered fracture across both flanges and panel zones in the WSMFs oriented in the north-south...
Journal Article
Published: 01 May 2003
Earthquake Spectra (2003) 19 (2): 269–290.
...C. Mark Saunders, M.EERI The damage to steel moment frames observed in the Northridge earthquake of 1994 led to requirements in codes for use of tested connections, when these systems were to be employed in new buildings. One of the primary goals of the FEMA/SAC project was to develop guidelines...
Image
Natural modes of four representative <span class="search-highlight">steel</span> <span class="search-highlight">moment</span> <span class="search-highlight">frame</span> <span class="search-highlight">buildings</span>          ...
Published: 01 May 2021
Table 3. Natural modes of four representative steel moment frame buildings Building Mode 1 Period Frequency Mode 2 Period Frequency Mode 3 Period Frequency Three story 0.606 s 1.65 Hz 0.191 s 5.24 Hz 0.097 s 10.34 Hz Nine story 2.13 s 0.469 Hz 0.734 s 1.36 Hz 0.410 s
Image
Representative <span class="search-highlight">steel</span> <span class="search-highlight">moment</span> <span class="search-highlight">frame</span> <span class="search-highlight">buildings</span> in the infrastructure model lib...
Published: 01 May 2021
Figure 10. Representative steel moment frame buildings in the infrastructure model library; 40-, 20-, 9-, and 3-story building models, Nevada finite-deformation, and co-rotational fiber-based nonlinear beam element for elasto-plastic materials.
Journal Article
Published: 01 November 2016
Earthquake Spectra (2016) 32 (4): 2271–2289.
... frames , Earthquake Engineering and Structural Dynamics 43 , 1935 – 1954 . Elkady A. , and Lignos D. G. , 2015 . Effect of gravity framing on the overstrength and collapse capacity of steel frame buildings with perimeter special moment frames , Earthquake...
FIGURES | View All (11)
Journal Article
Published: 01 November 2009
Earthquake Spectra (2009) 25 (4): 927–953.
...Bruce F. Maison; Kazuhiko Kasai; Gregory Deierlein A welded steel moment-frame building is used to assess performance-based engineering guidelines. The full-scale four-story building was shaken to collapse on the E-Defense shake table in Japan. The collapse mode was a side-sway mechanism...
Image
Nine-story symmetric-plan <span class="search-highlight">steel</span>-<span class="search-highlight">moment</span> <span class="search-highlight">frame</span> <span class="search-highlight">building</span> in Aliso Viejo, Calif...
Published: 01 August 2015
Figure 1. Nine-story symmetric-plan steel-moment frame building in Aliso Viejo, California (looking toward the northwest).
Journal Article
Published: 01 February 2000
Earthquake Spectra (2000) 16 (1): 179–203.
... developed in response to the damage suffered to steel moment frame buildings in the Northridge earthquake. The first, FEMA 267, Interim Guidelines: Evaluation, Repair, Modification and Design of Welded Steel Moment Frame Structures , was generated from studies undertaken as part of a project initiated...